Brahma
Fornitori di sistemi di combustione e controllo della fiamma
+39 0442 635211
Fornitori di sistemi di combustione e controllo della fiamma
Ignition transformers with very reduced overall dimensions suitable for gas forced draught burners and light or heavy oil
burners, both in domestic and industrial applications.
Regulations:
C22.2 1st Ed
UL 506 13th Ed
Product applications:
![]() | 220-240VAC - 50/60Hz 110-120VAC - 50/60Hz 24VAC - 50/60Hz 24VDC |
![]() | -10°C ÷ 60°C |
![]() | TCD1 1pole TCD2 2poles |
![]() | TC-TD...A* - 50% in 2 minuti |
TC-TD...S** - 100% | |
![]() | option |
![]() | TC 420gr |
TD 360gr | |
![]() | TCxL-TDxL 86 x 86/92 x 35,5 mm |
TCxS-TDxS 86 x 70/76 x 54,5 mm | |
![]() | Lateral isolators (TCxL-TDxL) |
Bottom isolators (TCxS-TDxS) | |
![]() | Ø4 mm cylindrical terminal (TCxxT-TDxxT) |
screw (TCxxV-TDxxV) | |
![]() | In-built cable (TCDxxxC) |
Triangular plug (TCDxxxP) | |
![]() | 560mm |
![]() | 1,5mm |
![]() | 3÷5 mm |
* TC-TD…A – NON PERMANENT OPERATION /** TC-TD…S – PERMANENT OPERATION
220-240 VAC | ||||
TC1 TD1 xxxAx | TC1 TD1 xxxSx | TC2 TD2 xxxAx | TC2 TD2 xxxSx | |
![]() | 15 | 15 | 2x12 | 2x12 |
![]() | 25 | 15 | 30 | 20 |
![]() | 45 | 25 | 29 | 30 |
110-120 VAC | ||||
TC1 TD1 xxxAx | TC1 TD1 xxxSx | TC2 TD2 xxxAx | TC2 TD2 xxxSx | |
![]() | 15 | 15 | 2x12 | 2x12 |
![]() | 20 | 14 | 27 | 20 |
![]() | 45 | 25 | 55 | 30 |
24 VAC | 24 VDC | |||
TC1 TD1 xxxAx | TC1 TD1 xxxSx | TC2 TD2 xxxAx | TC2 TD2 xxxSx | |
![]() | 15 | 2x12 | 15 | 2x12 |
![]() | 19 | 26 | 17 | 25 |
![]() | 65VA | 79VA | 38W | 52W |
Fornitori di sistemi di combustione e controllo della fiamma
Customized and innovative solutions for each customer.