Electronic ignition transformers characterized by extremely small overall dimensions, suitable for equipping gas
and oil
burners, in civil and industrial applications.
NEW VERSIONS
Each ignition unit integrates an electronic timer, with the task of decreasing the discharge energy after a preset time interval. The inclusion of the timing function makes the transformer a continuous operation ignition unit, but with a significantly higher initial energy. For this reason, the presence of the timer is notably advantageous for all applications that require a continuous discharge, and still guarantees the possibility of intermittent operation.</>
C22.2 1st Ed
EN 61558-1:2005+A1:2009
EN 61558-2-3:2010
UL 506 13th Ed
Product applications:
| 230VAC - 50/60Hz 110-120VAC - 50/60Hz | |
| 230 Vac -20°C ÷ 60°C 110-120 Vac -20°C ÷ 60°C UL 110-120 Vac -20°C ÷ 50°C | |
| TT1 1 pole TT2 2 poles | |
| TTx* -33% in 3 min. | |
| TTx** - 100% | |
| STANDARD | |
| 250gr | |
| 87,1x65,1x40,5 mm | |
| Cylindrical terminal Ø4 mm (standard) | |
| Screw (TTxxV) | |
| Fast-on (TTxF) | |
| Triangular plug (TTxB) | |
| 1,5m | |
| 3÷5 mm |
* TT – NON PERMANENT OPERATION /** TT – PERMANENT OPERATION
| 230 VAC | ||||
| TT1 | TT2 | |||
| up to 60s | after 60s | up to 60s | after 60s | |
| 17 | 17 | 2x13 | 2x13 | |
| 37 | 26 | 30 | 21 | |
| 31 | 23 | 29 | 19 | |
| 110-120 VAC | ||||
| TT1 | TT2 | |||
| up to 60s | after 60s | up to 60s | after 60s | |
| 17 | 17 | 2x13 | 2x13 | |
| 34 | 25 | 27 | 19 | |
| 28 | 20 | 25 | 18 |